Same blood. Different number.
The exact same drop of blood, on three lab machines:
Illustration — example only, not a real result (ng/mL).
Nothing about the blood changed — only the machine did.
the science ↓
There isn't one universal AMH test. The same tube of blood can come back with different numbers depending on which lab machine measured it — Roche, Beckman, or an older manual ELISA each read a bit differently.
Source: Nelson SM et al. 'Variation in the Measurement of Anti-Müllerian Hormone – What Are the Laboratory Issues?' Frontiers in Endocrinology 2021;12:719029 ↗Compared head-to-head, the Roche Elecsys machine tends to report a lower AMH number than the older Gen II ELISA on the very same sample — the gap between the two methods has been measured anywhere from about -25% to +45%.
Source: Nelson SM et al. Frontiers in Endocrinology 2021;12:719029 ↗The Beckman Access test often reads higher than the Roche Elecsys test on the same blood — different enough that in one study around 29% of women would have been sorted into a different medication-dosing band just because of which machine was used.
Source: Nelson SM et al. Frontiers in Endocrinology 2021;12:719029 ↗When researchers ran the exact same samples on both the Roche and Beckman automated machines, the numbers still differed by a few percent and in a consistent direction, even though the two tests tracked each other closely.
Source: Bidlingmaier / Kansakoski-style paediatric reference interval study: 'Paediatric reference intervals for plasma anti-Müllerian hormone: comparison of Roche Elecsys and Beckman Coulter Access assays using the same cohort of samples,' Ann Clin Biochem (PMC6688133) ↗It's not only the brand of machine — the same test run in different labs can disagree a lot. In one quality-check program, individual results scattered from about 38% below to 55% above the true value, so it's best to stick with one lab over time.
Source: Rustamov O et al. 'Within-laboratory and between-laboratory variability in the measurement of anti-Müllerian hormone determined within an external quality assurance scheme,' Reprod Biol 2013 (PubMed 24011198) ↗For years there was no universal 'gold ruler' for AMH, which is exactly why the machines disagree. The WHO finally issued a shared reference material in 2020, but it didn't work equally well on every machine — so full standardization is still a work in progress.
Source: Ferguson JM et al. 'Establishment of a WHO Reference Reagent for anti-Müllerian hormone,' Reprod Biol Endocrinol 2020;18:86 (PMC7429692) ↗Just to learn from. Not a medical test.